Energy |
The EnergyConsumptionResponse type exposes the following members.
| Name | Description | |
|---|---|---|
| CurrentNow | The instantaneous amount of current recorded at EndTime (in Ampere) | |
| CurrentNowRYB | The instantaneous amount of current recorded at EndTime on three phases (in Ampere) | |
| EndTime | The end time of the sample period. Coincides with the time when request was received. | |
| EnergyUsed | The total amount of energy consumed during the sample period (in kilowatt-hours) | |
| FrequencyNow | The instantaneous frequency value recorded at EndTime (in Hertz) | |
| MeanCurrent | The average amount of current consumed during the sample period (in Ampere) | |
| MeanCurrentRYB | The average amount of current consumed during the sample period on three phases (in Ampere) | |
| MeanFrequency | The average frequency value recorded during the sample period (in Hertz) | |
| MeanPower | The average amount of power consumed during the sample period (in watts) | |
| MeanPowerRYB | The average amount of power consumed during the sample period on three phases (in watts) | |
| MeanVoltage | The average value of voltage measured during the sample period (in Volts DC or AC (RMS)) | |
| MeanVoltageRYB | The average value of voltage measured during the sample period on three phases (in Volts DC or AC (RMS)) | |
| MinimumCurrent | The minimum amount of current recorded during the sample period (in Ampere) | |
| MinimumCurrentRYB | The minimum amount of current recorded during the sample period on three phases (in Ampere) | |
| MinimumFrequency | The minimum frequency value recorded during the sample period (in Hertz) | |
| MinimumPower | The lowest amount of power recorded during the sample period (in watts) | |
| MinimumPowerRYB | The lowest amount of power recorded during the sample period on three phases (in watts) | |
| MinimumVoltage | The minimum amount of voltage recorded during the sample period (in Volts DC or AC (RMS)) | |
| MinimumVoltageRYB | The minimum amount of voltage recorded during the sample period on three phases (in Volts DC or AC (RMS)) | |
| PeakCurrent | The maximum amount of current recorded during the sample period (in Ampere) | |
| PeakCurrentRYB | The maximum amount of current recorded during the sample period on three phases (in Ampere) | |
| PeakFrequency | The maximum frequency value recorded during the sample period (in Hertz) | |
| PeakPower | The maximum amount of power recorded during the sample period (in watts) | |
| PeakPowerRYB | The maximum amount of power recorded during the sample period on three phases (in watts) | |
| PeakVoltage | The maximum amount of voltage recorded during the sample period (in Volts DC or AC (RMS)) | |
| PeakVoltageRYB | The maximum amount of voltage recorded during the sample period on three phases (in Volts DC or AC (RMS)) | |
| PowerFactorNow | Description (Coefficient number between 0.0 and 1.0 ) | |
| PowerFactorNowRYB | Description (Coefficient number between 0.0 and 1.0 ) | |
| PowerNow | The instantaneous amount of power recorded at EndTime (in watts) | |
| PowerNowRYB | The instantaneous amount of power recorded at EndTime on three phases (in watts) | |
| Result | The result of the request | |
| StartTime | The start time of the sample period. Start time is set as the start time of the immediately prior CFX.ResourcePerformance.EnergyConsumed message | |
| ThreePhaseNeutralCurrentNow | The instantanous amount of current on Neutral at EndTime (in Ampere) | |
| VoltageNow | The instantaneous value of voltage recorded at EndTime (in Volts DC or AC (RMS)) | |
| VoltageNowRYB | The instantaneous amount of voltage recorded at EndTime on three phases (in Volts DC or AC (RMS)) |