Click or drag to resize

UnitsArrived Class

Sent when production units physically arrives at a process endpoint, prior to any work or other activity commencing.
{
  "UnitCount": 2,
  "Units": [
    {
      "UnitIdentifier": "CARRIER5566",
      "PositionNumber": 1,
      "PositionName": "CIRCUIT1",
      "X": 50.45,
      "Y": 80.66,
      "Rotation": 0.0,
      "FlipX": false,
      "FlipY": false
    },
    {
      "UnitIdentifier": "CARRIER5566",
      "PositionNumber": 2,
      "PositionName": "CIRCUIT2",
      "X": 50.45,
      "Y": 80.66,
      "Rotation": 90.0,
      "FlipX": false,
      "FlipY": false
    }
  ]
}
Inheritance Hierarchy
SystemObject
  CFXCFXMessage
    CFX.ProductionUnitsArrived

Namespace: CFX.Production
Assembly: CFX (in CFX.dll) Version: 1.7.3
Syntax
public class UnitsArrived : CFXMessage

The UnitsArrived type exposes the following members.

Constructors
 NameDescription
Public methodUnitsArrived Default constructor
Top
Properties
 NameDescription
Public propertyHermesIdentifier The Hermes BoardId of the carrier, a PCB panel or single production unit. If a single production unit is moving through the process, this would be the actual unique identifier of that individual unition unit. However, if multiple production units are moving through the process as a group (as in the case of a PCB panel, a fixture, or any sort of carrier), this would be an identifier that represents the entire group of units, such as a carrier UID, a PCB panel UID, etc. HermesIdentifier will be transfered between all machines which support Hermes. The PrimaryIdentifier is containing a barcode information. Both can be transferred.
Remarks
Espcially when the line does not support the Hermes standard in the hole line, the Hermes Identifier can be unique only in the a part of the line. The Primary Identifier can be used to correlate the parts of hermes sublines to correlate this data as well.
Public propertyLane Lane identifier. Null if no specific lane
Public propertyPrimaryIdentifier The barcode, RFID, etc. that was most recently acquired by the scanner / reader. If a single production unit is moving through the process, this would be the actual unique identifier of that individual unition unit. However, if multiple production units are moving through the process as a group (as in the case of a PCB panel, a fixture, or any sort of carrier), this would be an identifier that represents the entire group of units, such as a carrier UID, a PCB panel UID, etc.
Public propertyUnitCount The number of individual production units
Public propertyUnits An optional list of structures that identify each specific instance of production unit that arrived (if known). Could be individual units, or within a carrier, panel, etc.
Top
See Also