Sent by a process endpoint when units physically depart from a process endpoint.
This does not imply any information about any activity that may have taken place.
{
"UnitCount": 2,
"Units": [
{
"UnitIdentifier": "CARRIER5566",
"PositionNumber": 1,
"PositionName": "CIRCUIT1",
"X": 50.45,
"Y": 80.66,
"Rotation": 0.0,
"FlipX": false,
"FlipY": false
},
{
"UnitIdentifier": "CARRIER5566",
"PositionNumber": 2,
"PositionName": "CIRCUIT2",
"X": 50.45,
"Y": 80.66,
"Rotation": 90.0,
"FlipX": false,
"FlipY": false
}
]
}
Inheritance Hierarchy Namespace: CFX.ProductionAssembly: CFX (in CFX.dll) Version: 2.0.0+5bb1f71a933ed371a0f5f2d5e7db34c89b75f3ea
Syntaxpublic class UnitsDeparted : CFXMessage
Public Class UnitsDeparted
Inherits CFXMessage
The UnitsDeparted type exposes the following members.
Constructors
Properties | Name | Description |
---|
 | HermesIdentifier |
The Hermes BoardId of the carrier, a PCB panel or single production unit. If a single production unit is moving through the
process, this would be the actual unique identifier of that individual unition unit. However, if multiple production units are moving
through the process as a group (as in the case of a PCB panel, a fixture, or any sort of carrier), this would be an identifier that
represents the entire group of units, such as a carrier UID, a PCB panel UID, etc.
HermesIdentifier will be transfered between all machines which support Hermes. The PrimaryIdentifier is containing a barcode information.
Both can be transferred.
Remarks
Espcially when the line does not support the Hermes standard in the hole line, the Hermes Identifier can be unique only in the a part
of the line. The Primary Identifier can be used to correlate the parts of hermes sublines to correlate this data as well.
|
 | Lane |
Lane identifier. Null if no specific lane
|
 | PrimaryIdentifier |
The barcode, RFID, etc. that was most recently acquired by the scanner / reader. If a single production unit is moving through the
process, this would be the actual unique identifier of that individual unition unit. However, if multiple production units are moving
through the process as a group (as in the case of a PCB panel, a fixture, or any sort of carrier), this would be an identifier that
represents the entire group of units, such as a carrier UID, a PCB panel UID, etc.
|
 | UnitCount |
The number of individual production units
|
 | Units |
An optional list of structures that identify each specific instance of production unit that arrived (if known).
Could be individual units, or within a carrier, panel, etc.
|
Top
See Also