Click or drag to resize

WorkStarted Class

Sent by a process endpoint when the work-cycle for a unit or group of units starts
{
  "TransactionID": "2c24590d-39c5-4039-96a5-91900cecedfa",
  "Lane": 1,
  "UnitCount": 2,
  "Units": [
    {
      "UnitIdentifier": "CARRIER5566",
      "PositionNumber": 1,
      "PositionName": "CIRCUIT1",
      "X": 50.45,
      "Y": 80.66,
      "Rotation": 0.0,
      "FlipX": false,
      "FlipY": false
    },
    {
      "UnitIdentifier": "CARRIER5566",
      "PositionNumber": 2,
      "PositionName": "CIRCUIT2",
      "X": 70.45,
      "Y": 80.66,
      "Rotation": 90.0,
      "FlipX": false,
      "FlipY": false
    }
  ]
}
Inheritance Hierarchy
SystemObject
  CFXCFXMessage
    CFX.ProductionWorkStarted

Namespace: CFX.Production
Assembly: CFX (in CFX.dll) Version: 1.7.3
Syntax
public class WorkStarted : CFXMessage

The WorkStarted type exposes the following members.

Constructors
 NameDescription
Public methodWorkStarted Default constructor
Top
Properties
 NameDescription
Public propertyHermesIdentifier The Hermes BoardId of the carrier, a PCB panel or single production unit. If a single production unit is moving through the process, this would be the actual unique identifier of that individual unition unit. However, if multiple production units are moving through the process as a group (as in the case of a PCB panel, a fixture, or any sort of carrier), this would be an identifier that represents the entire group of units, such as a carrier UID, a PCB panel UID, etc. HermesIdentifier will be transfered between all machines which support Hermes. The PrimaryIdentifier is containing a barcode information. Both can be transferred.
Remarks
Espcially when the line does not support the Hermes standard in the hole line, the Hermes Identifier can be unique only in the a part of the line. The Primary Identifier can be used to correlate the parts of hermes sublines to correlate this data as well.
Public propertyLane Lane identifier. Null if no specific lane
Public propertyPrimaryIdentifier The barcode, RFID, etc. that was most recently acquired by the scanner / reader. If a single production unit is moving through the process, this would be the actual unique identifier of that individual unition unit. However, if multiple production units are moving through the process as a group (as in the case of a PCB panel, a fixture, or any sort of carrier), this would be an identifier that represents the entire group of units, such as a carrier UID, a PCB panel UID, etc.
Public propertyTransactionID Transaction ID used to attach events and data during subsequent processing, until WorkCompleted
Public propertyUnitCount The number of individual production units associated with this transaction. May be more than 1 in the case of a carrier or panel of multiple PCB’s.
Public propertyUnits Data that identifies each specific instance of production unit with a carrier or panel.
Top