Energy |
The EnergyConsumptionResponse type exposes the following members.
Name | Description | |
---|---|---|
![]() | CurrentNow | The instantaneous amount of current recorded at EndTime (in Ampere) |
![]() | CurrentNowRYB | The instantaneous amount of current recorded at EndTime on three phases (in Ampere) |
![]() | EndTime | The end time of the sample period. Coincides with the time when request was received. |
![]() | EnergyUsed | The total amount of energy consumed during the sample period (in kilowatt-hours) |
![]() | FrequencyNow | The instantaneous frequency value recorded at EndTime (in Hertz) |
![]() | MeanCurrent | The average amount of current consumed during the sample period (in Ampere) |
![]() | MeanCurrentRYB | The average amount of current consumed during the sample period on three phases (in Ampere) |
![]() | MeanFrequency | The average frequency value recorded during the sample period (in Hertz) |
![]() | MeanPower | The average amount of power consumed during the sample period (in watts) |
![]() | MeanPowerRYB | The average amount of power consumed during the sample period on three phases (in watts) |
![]() | MeanVoltage | The average value of voltage measured during the sample period (in Volts DC or AC (RMS)) |
![]() | MeanVoltageRYB | The average value of voltage measured during the sample period on three phases (in Volts DC or AC (RMS)) |
![]() | MinimumCurrent | The minimum amount of current recorded during the sample period (in Ampere) |
![]() | MinimumCurrentRYB | The minimum amount of current recorded during the sample period on three phases (in Ampere) |
![]() | MinimumFrequency | The minimum frequency value recorded during the sample period (in Hertz) |
![]() | MinimumPower | The lowest amount of power recorded during the sample period (in watts) |
![]() | MinimumPowerRYB | The lowest amount of power recorded during the sample period on three phases (in watts) |
![]() | MinimumVoltage | The minimum amount of voltage recorded during the sample period (in Volts DC or AC (RMS)) |
![]() | MinimumVoltageRYB | The minimum amount of voltage recorded during the sample period on three phases (in Volts DC or AC (RMS)) |
![]() | PeakCurrent | The maximum amount of current recorded during the sample period (in Ampere) |
![]() | PeakCurrentRYB | The maximum amount of current recorded during the sample period on three phases (in Ampere) |
![]() | PeakFrequency | The maximum frequency value recorded during the sample period (in Hertz) |
![]() | PeakPower | The maximum amount of power recorded during the sample period (in watts) |
![]() | PeakPowerRYB | The maximum amount of power recorded during the sample period on three phases (in watts) |
![]() | PeakVoltage | The maximum amount of voltage recorded during the sample period (in Volts DC or AC (RMS)) |
![]() | PeakVoltageRYB | The maximum amount of voltage recorded during the sample period on three phases (in Volts DC or AC (RMS)) |
![]() | PowerFactorNow | Description (Coefficient number between 0.0 and 1.0 ) |
![]() | PowerFactorNowRYB | Description (Coefficient number between 0.0 and 1.0 ) |
![]() | PowerNow | The instantaneous amount of power recorded at EndTime (in watts) |
![]() | PowerNowRYB | The instantaneous amount of power recorded at EndTime on three phases (in watts) |
![]() | Result | The result of the request |
![]() | StartTime | The start time of the sample period. Start time is set as the start time of the immediately prior CFX.ResourcePerformance.EnergyConsumed message |
![]() | ThreePhaseNeutralCurrentNow | The instantanous amount of current on Neutral at EndTime (in Ampere) |
![]() | VoltageNow | The instantaneous value of voltage recorded at EndTime (in Volts DC or AC (RMS)) |
![]() | VoltageNowRYB | The instantaneous amount of voltage recorded at EndTime on three phases (in Volts DC or AC (RMS)) |