Condition |
The ConditionResult type exposes the following members.
Name | Description | |
---|---|---|
![]() | ConditionOperator | Describes the Operator who ran the condition step (optional) |
![]() | ConditionSequence | Describes Condition sequence that was executed |
![]() | ConditionStatus | Describes result of the condition sequence |
![]() | HermesIdentifier |
The Hermes BoardId of the carrier, a PCB panel or single production unit. If a single production unit is moving through the
process, this would be the actual unique identifier of that individual unition unit. However, if multiple production units are moving
through the process as a group (as in the case of a PCB panel, a fixture, or any sort of carrier), this would be an identifier that
represents the entire group of units, such as a carrier UID, a PCB panel UID, etc.
HermesIdentifier will be transfered between all machines which support Hermes. The PrimaryIdentifier is containing a barcode information.
Both can be transferred.
![]()
Espcially when the line does not support the Hermes standard in the hole line, the Hermes Identifier can be unique only in the a part
of the line. The Primary Identifier can be used to correlate the parts of hermes sublines to correlate this data as well.
|
![]() | PrimaryIdentifier | The barcode, RFID, etc. that was most recently acquired by the scanner / reader. If a single production unit is moving through the process, this would be the actual unique identifier of that individual unition unit. However, if multiple production units are moving through the process as a group (as in the case of a PCB panel, a fixture, or any sort of carrier), this would be an identifier that represents the entire group of units, such as a carrier UID, a PCB panel UID, etc. |
![]() | TransactionID | Transaction ID used to attach events and data during subsequent processing, until WorkCompleted |
![]() | Units | Data that identifies each specific instance of production unit with a carrier or panel. |